- Главная
- Каталог
- Omron
- Системы безопасности OMRON
- Программируемая система безопасности
Компания ГК Проминдустрия предлагает купить Программируемая система безопасности с доставкой по всей России.
Информация для заказа:
NX Safety Hybrid
NX1 series CPU units
CPU | Appearance | Program capacity | Variables capacity | Number of axes | Functionalities | Order code | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Real axes | Motion control servo axes | Single-axis position control axes | Sequence | OPC UA | Motion | DB connection | |||||
NX102 | 5 MB | 1.5 MB: Retained 32 MB: Not retained | 12 axes | 8 axes | 4 axes | ■ | ■ | ■ | ■ | NX102-1220 | |
■ | ■ | ■ | – | NX102-1200 | |||||||
8 axes | 4 axes | ■ | ■ | ■ | ■ | NX102-1120 | |||||
■ | ■ | ■ | – | NX102-1100 | |||||||
6 axes | 2 axes | ■ | ■ | ■ | ■ | NX102-1020 | |||||
■ | ■ | ■ | – | NX102-1000 | |||||||
4 axes | 0 axes | ■ | ■ | – | ■ | NX102-9020 | |||||
■ | ■ | – | – | NX102-9000 |
The end cover unit NX-END02 is included with the CPU unit.
NX-series Safety Control Units
Safety CPU Units
Unit type | Appearance | Specifications | Unit version | Order code | |||
---|---|---|---|---|---|---|---|
Maximum number of safety I/O points | Program capacity | Number of safety I/O connections | I/O refreshing method | ||||
Safety CPU Unit (NX-SL5⬜⬜⬜) | 1024 points | 2048 KB | 128 | Free-Run refreshing | Ver. 1.3 | NX-SL5500 | |
2032 points | 4096 KB | 254 | NX-SL5700 |
Refer to your local OMRON website for details of the NX-SL5⬜⬜⬜ Safety CPU Unit.
Safety Input Units
Unit type | Appearance | Specifications | Unit version | Order code | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of safety input points | Number of test output points | Internal I/O common | Rated input voltage | OMRON special safety input devices | Number of safety slave connections | I/O refreshing method | ||||
Safety Input Units | 4 points | 2 points | Sinking inputs (PNP) | 24 VDC | Cannot be connected. | 1 | Free-Run refreshing | Ver. 1.1 | NX-SIH400 | |
8 points | Cannot be connected. | Ver. 1.0 | NX-SID800 |
Safety Output Units
Unit type | Appearance | Specifications | Unit version | Order code | |||||
---|---|---|---|---|---|---|---|---|---|
Number of safety output points | Internal I/O common | Maximum load current | Rated voltage | Number of safety slave connections | I/O refreshing method | ||||
Safety Output Units | 2 points | Sourcing outputs (PNP) | 2.0 A/point, 4.0 A/Unit at 40°C, and 2.5 A/Unit at 55°C The maximum load current depends on the installation orientation and ambient temperature. | 24 VDC | 1 | Free-Run refreshing | Ver. 1.0 | NX-SOH200 | |
4 points | 0.5 A/point and 2.0 A/Unit | NX-SOD400 |
NX-series Standard I/O units
For the selection of standard I/O units please refer to the NX Series product website (https://industrial.omron.eu/en/products/nx-series).
Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
Product name | Specifications | Number of licenses | Media | Order code |
---|---|---|---|---|
Sysmac Studio Safety Edition Ver. 1.⬜⬜ | Sysmac Studio Safety Edition is a license including necessary setting functions for the safety control system. Note:This product is a license only. You need the Sysmac Studio Standard Edition DVD media to install it. | 1 license | – | SYSMAC-FE001L |
Sysmac Studio Standard Edition Ver. 1.⬜⬜ | The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI. Sysmac Studio runs on the following OS. Windows 7(32-bit/64-bit version)/8(32-bit/64-bit version)/8.1(32-bit/64-bit version)/10(32-bit/64-bit version) | – (Media only) | DVD | SYSMAC-SE200D |
For details of the Automation Software Sysmac Studio, refer to your local OMRON website.
Optional Products
Product name | Specifications | Order code |
---|---|---|
Memory Card | SD memory card, 2 GB | HMC-SD291 |
SD memory card, 4 GB | HMC-SD491 | |
Unit/Terminal Block Coding Pins | For 10 Units (Terminal Block: 30 pins, Unit: 30 pins) | NX-AUX02 |
Product name | Specifications | Order code | |||
---|---|---|---|---|---|
No. of terminals | Terminal number indications | Ground terminal mark | Terminal current capacity | ||
Terminal Block | 8 | A/B | Provided | 10 A | NX-TBC082 |
8 | A/B | None | 10 A | NX-TBA082 | |
16 | A/B | None | 10 A | NX-TBA162 |
Accessories
Communication Control Unit Accessories
Product name | Remark | Order code |
---|---|---|
End Cover | One End Cover is provided with the Communication Control Unit. | NX-END02 |
CIP Safety
NX-series Communication Gateway Unit
Unit type | Appearance | Supported communications protocol | Number of communications connectors | Network variables | Unit version | Order code |
---|---|---|---|---|---|---|
Communication Control Unit | EtherNet/IP | 3 | 2 | Ver. 1.01 | NX-CSG320 |
One NX-END02 End Cover is provided with the NX-CSG320 Communication Control Unit.
NX-series Safety Control Units
Safety CPU Units
Unit type | Appearance | Specifications | Unit version | Order code | |||
---|---|---|---|---|---|---|---|
Maximum number of safety I/O points | Program capacity | Number of safety I/O connections | I/O refreshing method | ||||
Safety CPU Unit (NX-SL5⬜⬜⬜) | 1024 points | 2048 KB | 128 | Free-Run refreshing | Ver. 1.3 | NX-SL5500 | |
2032 points | 4096 KB | 254 | NX-SL5700 |
Refer to your local OMRON website for details of the NX-SL5⬜⬜⬜ Safety CPU Unit.
Safety Input Units
Unit type | Appearance | Specifications | Unit version | Order code | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of safety input points | Number of test output points | Internal I/O common | Rated input voltage | OMRON special safety input devices | Number of safety slave connections | I/O refreshing method | ||||
Safety Input Units | 4 points | 2 points | Sinking inputs (PNP) | 24 VDC | Cannot be connected. | 1 | Free-Run refreshing | Ver. 1.1 | NX-SIH400 | |
8 points | Cannot be connected. | Ver. 1.0 | NX-SID800 |
Safety Output Units
Unit type | Appearance | Specifications | Unit version | Order code | |||||
---|---|---|---|---|---|---|---|---|---|
Number of safety output points | Internal I/O common | Maximum load current | Rated voltage | Number of safety slave connections | I/O refreshing method | ||||
Safety Output Units | 2 points | Sourcing outputs (PNP) | 2.0 A/point, 4.0 A/Unit at 40°C, and 2.5 A/Unit at 55°C The maximum load current depends on the installation orientation and ambient temperature. | 24 VDC | 1 | Free-Run refreshing | Ver. 1.0 | NX-SOH200 | |
4 points | 0.5 A/point and 2.0 A/Unit | NX-SOD400 |
Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
Product name | Specifications | Number of licenses | Media | Order code |
---|---|---|---|---|
Sysmac Studio Safety Edition Ver. 1.⬜⬜ | Sysmac Studio Safety Edition is a license including necessary setting functions for the safety control system. Note:This product is a license only. You need the Sysmac Studio Standard Edition DVD media to install it. | 1 license | – | SYSMAC-FE001L |
Sysmac Studio Standard Edition Ver. 1.⬜⬜ | The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI. Sysmac Studio runs on the following OS. Windows 7(32-bit/64-bit version)/8(32-bit/64-bit version)/8.1(32-bit/64-bit version)/10(32-bit/64-bit version) | – (Media only) | DVD | SYSMAC-SE200D |
For details of the Automation Software Sysmac Studio, refer to your local OMRON website.
Optional Products
Product name | Specifications | Order code |
---|---|---|
Memory Card | SD memory card, 2 GB | HMC-SD291 |
SD memory card, 4 GB | HMC-SD491 | |
Unit/Terminal Block Coding Pins | For 10 Units (Terminal Block: 30 pins, Unit: 30 pins) | NX-AUX02 |
Product name | Specifications | Order code | |||
---|---|---|---|---|---|
No. of terminals | Terminal number indications | Ground terminal mark | Terminal current capacity | ||
Terminal Block | 8 | A/B | Provided | 10 A | NX-TBC082 |
8 | A/B | None | 10 A | NX-TBA082 | |
16 | A/B | None | 10 A | NX-TBA162 |
Accessories
Communication Control Unit Accessories
Product name | Remark | Order code |
---|---|---|
End Cover | One End Cover is provided with the Communication Control Unit. | NX-END02 |
NX Safety distributed
odule Type | |||||
---|---|---|---|---|---|
Safety Digital I/O units
, I/O Refresh Mode | |||||
---|---|---|---|---|---|
Note: For a standard I/O unit please check the chapter NX-I/O.
Software tool
To program the NX-Series use the Sysmac studio software tool, please have a look on the section Software to select your licence
Accessories
Ethernet cables and accessories
EtherCAT patch cables, improved shield
Shape | Connector 1 | Connector 2 | Material | Cable | Color | Length in cm | Order code | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20 | 30 | 50 | 100 | 150 | 200 | 300 | 500 | 750 | 1000 | 1500 | 2000 | |||||||
| M12 straight | M12 straight | PVC | AWG22, 2 pairs | Black | – | – | ⬛ | ⬛ | – | ⬛ | ⬛ | ⬛ | – | ⬛ | – | – | XS5W-T421-[.]M2-SS |
| M12 straight | RJ45 | PVC | AWG22, 2 pairs | Black | – | – | ⬛ | ⬛ | – | ⬛ | ⬛ | ⬛ | – | ⬛ | – | – | XS5W-T421-[.]MC-SS |
Note: For [.] fill in the 1-character length code.
Ethernet patch cables, standard RJ45 connectors
Shape | Connector 1 | Connector 2 | Material | Cable | Color | Length in cm | Order code | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20 | 30 | 50 | 100 | 150 | 200 | 300 | 500 | 750 | 1000 | 1500 | 2000 | |||||||
| RJ45 std. | RJ45 std. | LSZH | Cat6a S/FTP 4 pairs | Blue | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | XS6W-6LSZH8SS[…]CM-B |
| RJ45 std. | RJ45 std. | LSZH | Cat6a S/FTP 4 pairs | Yellow | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | XS6W-6LSZH8SS[…]CM-Y |
| RJ45 std. | RJ45 std. | LSZH | Cat6a S/FTP 4 pairs | Green | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | XS6W-6LSZH8SS[…]CM-G |
| RJ45 std. | RJ45 std. | PUR | Cat5e S/FTP 4 pairs | Green | – | – | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | XS6W-5PUR8SS[…]CM-G |
Note: For […] fill in the length in cm.
Ethernet patch cables, RJ45/M12 connectors
Shape | Connector 1 | Connector 2 | Material | Cable | Color | Length in cm | Order code | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
30 | 50 | 100 | 200 | 300 | 500 | 1000 | 1500 | |||||||
| RJ45 | RJ45 | PVC | Cat5e Shielded Quad | Light Blue | A | B | C | D | E | G | J | K | XS5W-T421-[.]MD-K |
| M12 straight | M12 straight | PVC | Cat5e Shielded Quad | Light Blue | – | B | C | D | E | G | J | K | XS5W-T421-[.]M2-K |
| M12 straight | RJ45 | PVC | Cat5e Shielded Quad | Light Blue | A | B | C | D | E | G | J | K | XS5W-T421-[.]MC-K |
| M12 angled | M12 angled | PVC | Cat5e Shielded Quad | Light Blue | – | B | C | D | E | G | J | K | XS5W-T422-[.]M2-K |
| M12 angled | RJ45 | PVC | Cat5e Shielded Quad | Light Blue | A | B | C | D | E | G | J | K | XS5W-T422-[.]MC-K |
NX-Safety stand alone
Module Type | |||||
---|---|---|---|---|---|
Max. 512 bytes in + 512 bytes out Supports local safety communication | |||||
512 KB Safety program capacity |
Safety digital I/O units
, I/O Refresh Mode | |||||
---|---|---|---|---|---|
Note: For selecting the compatible NX Digital and Analog I/O units, please refer to the NX-series modular I/O system chapter from this catalogue, check the Sysmac Studio Software I/O edition software tool or visit our website. As this selection is technically not easy, is better to contact our Omron support.
Accessories
Ethernet cables and accessories
EtherCAT patch cables, improved shield
Shape | Connector 1 | Connector 2 | Material | Cable | Color | Length in cm | Order code | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20 | 30 | 50 | 100 | 150 | 200 | 300 | 500 | 750 | 1000 | 1500 | 2000 | |||||||
| M12 straight | M12 straight | PVC | AWG22, 2 pairs | Black | – | – | ⬛ | ⬛ | – | ⬛ | ⬛ | ⬛ | – | ⬛ | – | – | XS5W-T421-[.]M2-SS |
| M12 straight | RJ45 | PVC | AWG22, 2 pairs | Black | – | – | ⬛ | ⬛ | – | ⬛ | ⬛ | ⬛ | – | ⬛ | – | – | XS5W-T421-[.]MC-SS |
Note: For [.] fill in the 1-character length code.
Ethernet patch cables, standard RJ45 connectors
Shape | Connector 1 | Connector 2 | Material | Cable | Color | Length in cm | Order code | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20 | 30 | 50 | 100 | 150 | 200 | 300 | 500 | 750 | 1000 | 1500 | 2000 | |||||||
| RJ45 std. | RJ45 std. | LSZH | Cat6a S/FTP 4 pairs | Blue | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | XS6W-6LSZH8SS[…]CM-B |
| RJ45 std. | RJ45 std. | LSZH | Cat6a S/FTP 4 pairs | Yellow | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | XS6W-6LSZH8SS[…]CM-Y |
| RJ45 std. | RJ45 std. | LSZH | Cat6a S/FTP 4 pairs | Green | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | XS6W-6LSZH8SS[…]CM-G |
| RJ45 std. | RJ45 std. | PUR | Cat5e S/FTP 4 pairs | Green | – | – | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | ⬛ | XS6W-5PUR8SS[…]CM-G |
Note: For […] fill in the length in cm.
Ethernet patch cables, RJ45/M12 connectors
Shape | Connector 1 | Connector 2 | Material | Cable | Color | Length in cm | Order code | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
30 | 50 | 100 | 200 | 300 | 500 | 1000 | 1500 | |||||||
| RJ45 | RJ45 | PVC | Cat5e Shielded Quad | Light Blue | A | B | C | D | E | G | J | K | XS5W-T421-[.]MD-K |
| M12 straight | M12 straight | PVC | Cat5e Shielded Quad | Light Blue | – | B | C | D | E | G | J | K | XS5W-T421-[.]M2-K |
| M12 straight | RJ45 | PVC | Cat5e Shielded Quad | Light Blue | A | B | C | D | E | G | J | K | XS5W-T421-[.]MC-K |
| M12 angled | M12 angled | PVC | Cat5e Shielded Quad | Light Blue | – | B | C | D | E | G | J | K | XS5W-T422-[.]M2-K |
| M12 angled | RJ45 | PVC | Cat5e Shielded Quad | Light Blue | A | B | C | D | E | G | J | K | XS5W-T422-[.]MC-K |
NE1A-SCPU_
Appearance | |||
---|---|---|---|
Software
Accessories
G9SP-N_
Appearance | ||
---|---|---|
10 PNP safety inputs | ||
Software
Expansion units (standard I/O)
G9SP configuration
Option units
G9SP-N10S Display Kit (G9SP, Touchscreen, cable, CP1W-CIF01) | |
G9SP-N10D Display Kit (G9SP, Touchscreen, cable, CP1W-CIF01) | |
G9SP-N20S Display Kit (G9SP, Touchscreen, cable, CP1W-CIF01) | |
Для расчета стоимости и сроков поставки пишите на нашу электронную почту:
zakaz@gcprom.ru
zakaz@gcprom.ru