Компания ГК Проминдустрия предлагает купить Программируемая система безопасности с доставкой по всей России.

Информация для заказа:

NX Safety Hybrid

NX1 series CPU units

CPUAppearanceProgram capacityVariables capacityNumber of axesFunctionalitiesOrder code
Real axesMotion control servo axesSingle-axis position control axesSequenceOPC UAMotionDB connection
NX1025 MB

1.5 MB: Retained

32 MB: Not retained

12 axes8 axes4 axesNX102-1220
NX102-1200
8 axes4 axesNX102-1120
NX102-1100
6 axes2 axesNX102-1020
NX102-1000
4 axes0 axesNX102-9020
NX102-9000
Note:

The end cover unit NX-END02 is included with the CPU unit.

NX-series Safety Control Units

Safety CPU Units

Unit typeAppearanceSpecificationsUnit versionOrder code
Maximum number of safety I/O pointsProgram capacityNumber of safety I/O connectionsI/O refreshing method
Safety CPU Unit
(NX-SL5⬜⬜⬜)
1024 points2048 KB128Free-Run refreshingVer. 1.3NX-SL5500
2032 points4096 KB254NX-SL5700
Note:

Refer to your local OMRON website for details of the NX-SL5⬜⬜⬜ Safety CPU Unit.

Safety Input Units

Unit typeAppearanceSpecificationsUnit versionOrder code
Number of safety input pointsNumber of test output pointsInternal I/O commonRated input voltageOMRON special safety input devicesNumber of safety slave connectionsI/O refreshing method
Safety Input Units4 points2 pointsSinking inputs (PNP)24 VDCCannot be
connected.
1Free-Run refreshingVer. 1.1NX-SIH400
8 pointsCannot be
connected.
Ver. 1.0NX-SID800

Safety Output Units

Unit typeAppearanceSpecificationsUnit versionOrder code
Number of
safety output
points
Internal I/O
common
Maximum load currentRated
voltage
Number of
safety slave
connections
I/O refreshing
method
Safety Output Units2 pointsSourcing
outputs
(PNP)

2.0 A/point, 4.0 A/Unit at 40°C, and 2.5 A/Unit at 55°C

The maximum load current depends on the installation orientation and ambient temperature.

24 VDC1Free-Run refreshingVer. 1.0NX-SOH200
4 points0.5 A/point and 2.0 A/UnitNX-SOD400

NX-series Standard I/O units

For the selection of standard I/O units please refer to the NX Series product website (https://industrial.omron.eu/en/products/nx-series).

Automation Software Sysmac Studio

Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.

Product nameSpecificationsNumber of licensesMediaOrder code
Sysmac Studio
Safety Edition
Ver. 1.⬜⬜

Sysmac Studio Safety Edition is a license including necessary setting functions for the safety control system.

Note:This product is a license only. You need the Sysmac Studio Standard Edition DVD media to install it.
1 licenseSYSMAC-FE001L
Sysmac Studio
Standard Edition
Ver. 1.⬜⬜

The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI.

Sysmac Studio runs on the following OS.

Windows 7(32-bit/64-bit version)/8(32-bit/64-bit version)/8.1(32-bit/64-bit version)/10(32-bit/64-bit version)

– (Media only)DVDSYSMAC-SE200D
Note:

For details of the Automation Software Sysmac Studio, refer to your local OMRON website.

Optional Products

Product nameSpecificationsOrder code
Memory CardSD memory card, 2 GBHMC-SD291
SD memory card, 4 GBHMC-SD491
Unit/Terminal Block Coding PinsFor 10 Units (Terminal Block: 30 pins, Unit: 30 pins)NX-AUX02
Product nameSpecificationsOrder code
No. of terminalsTerminal number indicationsGround terminal markTerminal current capacity
Terminal Block8A/BProvided10 ANX-TBC082
8A/BNone10 ANX-TBA082
16A/BNone10 ANX-TBA162

Accessories

Communication Control Unit Accessories

Product nameRemarkOrder code
End CoverOne End Cover is provided with the Communication Control Unit.NX-END02

 

CIP Safety

NX-series Communication Gateway Unit

Unit typeAppearanceSupported communications protocolNumber of communications connectorsNetwork variablesUnit versionOrder code
Communication
Control Unit
EtherNet/IP32Ver. 1.01NX-CSG320
Note:

One NX-END02 End Cover is provided with the NX-CSG320 Communication Control Unit.

NX-series Safety Control Units

Safety CPU Units

Unit typeAppearanceSpecificationsUnit versionOrder code
Maximum number of safety I/O pointsProgram capacityNumber of safety I/O connectionsI/O refreshing method
Safety CPU Unit
(NX-SL5⬜⬜⬜)
1024 points2048 KB128Free-Run refreshingVer. 1.3NX-SL5500
2032 points4096 KB254NX-SL5700
Note:

Refer to your local OMRON website for details of the NX-SL5⬜⬜⬜ Safety CPU Unit.

Safety Input Units

Unit typeAppearanceSpecificationsUnit versionOrder code
Number of
safety input
points
Number of
test output
points
Internal I/O
common
Rated input
voltage
OMRON
special safety
input devices
Number of
safety slave
connections
I/O refreshing
method
Safety Input Units4 points2 pointsSinking inputs (PNP)24 VDCCannot be
connected.
1Free-Run refreshingVer. 1.1NX-SIH400
8 pointsCannot be
connected.
Ver. 1.0NX-SID800

Safety Output Units

Unit typeAppearanceSpecificationsUnit versionOrder code
Number of
safety output
points
Internal I/O
common
Maximum load currentRated
voltage
Number of
safety slave
connections
I/O refreshing
method
Safety Output Units2 pointsSourcing
outputs
(PNP)

2.0 A/point, 4.0 A/Unit at 40°C, and 2.5 A/Unit at 55°C

The maximum load current depends on the installation orientation and ambient temperature.

24 VDC1Free-Run refreshingVer. 1.0NX-SOH200
4 points0.5 A/point and 2.0 A/UnitNX-SOD400

Automation Software Sysmac Studio

Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.

Product nameSpecificationsNumber of licensesMediaOrder code
Sysmac Studio
Safety Edition
Ver. 1.⬜⬜

Sysmac Studio Safety Edition is a license including necessary setting functions for the safety control system.

Note:This product is a license only. You need the Sysmac Studio Standard Edition DVD media to install it.
1 licenseSYSMAC-FE001L
Sysmac Studio
Standard Edition
Ver. 1.⬜⬜

The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI.

Sysmac Studio runs on the following OS.

Windows 7(32-bit/64-bit version)/8(32-bit/64-bit version)/8.1(32-bit/64-bit version)/10(32-bit/64-bit version)

– (Media only)DVDSYSMAC-SE200D
Note:

For details of the Automation Software Sysmac Studio, refer to your local OMRON website.

Optional Products

Product nameSpecificationsOrder code
Memory CardSD memory card, 2 GBHMC-SD291
SD memory card, 4 GBHMC-SD491
Unit/Terminal Block Coding PinsFor 10 Units (Terminal Block: 30 pins, Unit: 30 pins)NX-AUX02
Product nameSpecificationsOrder code
No. of terminalsTerminal number indicationsGround terminal markTerminal current capacity
Terminal Block8A/BProvided10 ANX-TBC082
8A/BNone10 ANX-TBA082
16A/BNone10 ANX-TBA162

Accessories

Communication Control Unit Accessories

Product nameRemarkOrder code
End CoverOne End Cover is provided with the Communication Control Unit.NX-END02

 

NX Safety distributed

odule Type

Protocol

Connection

Specification

Width

Order Code

Communication coupler

EtherCAT Slave

2 RJ45 ports

(in + out)

Up to 63 I/O units.

Max. 1,024 bytes in + 1,024 bytes out

Supports distributed clock

I/O power supply up to 10 A

46 mm

NX-ECC203

Safety controller integrated

NX-Bus

128 Safety connections

Up to 2 MB Safety program capacity

Up to 128 Safety slices

Up to 1024 safety I/O points

Safety and standard digital/analog slices can be connected

30 mm

NX-SL3500

32 Safety connections

512 KB Safety program capacity

Up to 32 Safety slices

Up to 256 safety I/O points

Safety and standard digital/analog slices can be connected

30 mm

NX-SL3300

Safety Digital I/O units

Module type

Channels, Signal type

Performance

, I/O Refresh Mode

Connection type

Width

Order Code

Safety Digital Input

4 inputs + 2 test outputs

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-SIH400

8 inputs + 2 test outputs

Free Run

Screwless push-in (NX-TBA162)

12 mm

NX-SID800

Safety Digital Output

2 outputs, 2.0 A

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-SOH200

4 outputs, 0.5 A

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-SOD400

Note: For a standard I/O unit please check the chapter NX-I/O.

Software tool

To program the NX-Series use the Sysmac studio software tool, please have a look on the section Software to select your licence

 
 

Accessories

Ethernet cables and accessories

EtherCAT patch cables, improved shield

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

 

M12 straight

M12 straight

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]M2-SS

 

M12 straight

RJ45

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]MC-SS

Note: For [.] fill in the 1-character length code.

Ethernet patch cables, standard RJ45 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Blue

XS6W-6LSZH8SS[…]CM-B

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Yellow

XS6W-6LSZH8SS[…]CM-Y

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Green

XS6W-6LSZH8SS[…]CM-G

 

RJ45 std.

RJ45 std.

PUR

Cat5e S/FTP 4 pairs

Green

XS6W-5PUR8SS[…]CM-G

Note: For […] fill in the length in cm.

Ethernet patch cables, RJ45/M12 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

30

50

100

200

300

500

1000

1500

 

RJ45

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MD-K

 

M12 straight

M12 straight

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T421-[.]M2-K

 

M12 straight

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MC-K

 

M12 angled

M12 angled

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T422-[.]M2-K

 

M12 angled

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T422-[.]MC-K

 

NX-Safety stand alone

Module Type

Protocol

Connection

Specification

Width

Order Code

Communication coupler

EtherNet/IP Slave

2 RJ45 ports

with built-in switch

Up to 63 I/O units.

Max. 512 bytes in + 512 bytes out

Supports local safety communication

Free Run I/O refresh mode only

I/O power supply up to 10 A

46 mm

NX-EIC202

Safety controller

NX-Bus

32 Safety connections

512 KB Safety program capacity

Up to 63 Safety/Standard slices

Max. 32 Safety slices

Up to 256 safety I/O points

Safety and standard digital/analog slices can be connected

30 mm

NX-SL3300

Safety digital I/O units

Module type

Channels, Signal type

Performance

, I/O Refresh Mode

Connection type

Width

Order Code

Safety Digital Input

4 inputs + 2 test outputs

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-SIH400

8 inputs + 2 test outputs

Free Run

Screwless push-in (NX-TBA162)

12 mm

NX-SID800

Safety Digital Output

2 outputs, 2.0 A

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-SOH200

4 outputs, 0.5 A

Free Run

Screwless push-in (NX-TBA082)

12 mm

NX-SOD400

Note: For selecting the compatible NX Digital and Analog I/O units, please refer to the NX-series modular I/O system chapter from this catalogue, check the Sysmac Studio Software I/O edition software tool or visit our website. As this selection is technically not easy, is better to contact our Omron support.

 
 

Accessories

Ethernet cables and accessories

EtherCAT patch cables, improved shield

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

 

M12 straight

M12 straight

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]M2-SS

 

M12 straight

RJ45

PVC

AWG22, 2 pairs

Black

XS5W-T421-[.]MC-SS

Note: For [.] fill in the 1-character length code.

Ethernet patch cables, standard RJ45 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

20

30

50

100

150

200

300

500

750

1000

1500

2000

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Blue

XS6W-6LSZH8SS[…]CM-B

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Yellow

XS6W-6LSZH8SS[…]CM-Y

 

RJ45 std.

RJ45 std.

LSZH

Cat6a S/FTP 4 pairs

Green

XS6W-6LSZH8SS[…]CM-G

 

RJ45 std.

RJ45 std.

PUR

Cat5e S/FTP 4 pairs

Green

XS6W-5PUR8SS[…]CM-G

Note: For […] fill in the length in cm.

Ethernet patch cables, RJ45/M12 connectors

Shape

Connector 1

Connector 2

Material

Cable

Color

Length in cm

Order code

30

50

100

200

300

500

1000

1500

 

RJ45

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MD-K

 

M12 straight

M12 straight

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T421-[.]M2-K

 

M12 straight

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T421-[.]MC-K

 

M12 angled

M12 angled

PVC

Cat5e Shielded Quad

Light Blue

B

C

D

E

G

J

K

XS5W-T422-[.]M2-K

 

M12 angled

RJ45

PVC

Cat5e Shielded Quad

Light Blue

A

B

C

D

E

G

J

K

XS5W-T422-[.]MC-K

 

NE1A-SCPU_

Appearance

Appearance description

Interface

Order code

Safety network
controller

16 PNP inputs

8 PNP outputs

4 test outputs

254 function block programming

removable cage clamp terminals

USB and
DeviceNet safety

NE1A-SCPU01-V1

Ethernet/IP and
DeviceNet safety

NE1A-SCPU01-EIP

40 PNP inputs

8 PNP outputs

8 test outputs

254 function block programming

removable cage clamp terminals

USB and

DeviceNet safety

NE1A-SCPU02

Ethernet/IP and

DeviceNet safety

NE1A-SCPU02-EIP

Software

Appearance

Appearance description

Order code

Safety network
configurator

Installation disk (CD-ROM)

IBM PC/AT compatible

Windows 2000, Windows XP, Windows 7

WS02-CFSC1-E

Accessories

Appearance

Appearance description

Order code

Network router

Ethernet/IP – DeviceNet router

NE1A-EDR01

Programming console

CF-Card slot to store configuration

USB-Interface for maintenance

Touchscreen for easy troubleshooting

NE1A-HDY

G9SP-N_

Appearance

Appearance description

Order code

Standalone
safety controller

10 PNP safety inputs
4 PNP safety outputs
4 test outputs
4 PNP standard outputs

G9SP-N10S

10 PNP safety inputs
16 PNP safety outputs
6 test outputs

G9SP-N10D

20 PNP safety inputs
8 PNP safety outputs
6 test outputs

G9SP-N20S

Software

Appearance

Media

Applicable OS

Order code

G9SP
configurator

Setup disk 1 license

Windows 2000
Windows XP
Windows Vista
Windows 7

WS02-G9SP01-V1

Setup disk 10 licenses

WS02-G9SP10-V1

Setup disk 50 licenses

WS02-G9SP50-V1

Setup disk Site license

WS02-G9SPXX-V1

Expansion units (standard I/O)

Appearance

Type

Number of I/O

Model

In

Out

Expansion I/O unit

Sinking

12

8 (solid state)

CP1W-20EDT

Sourcing

12

8 (solid state)

CP1W-20EDT1

Sinking

32 (solid state)

CP1W-32ET

Sourcing

32 (solid state)

CP1W-32ET1

I/O Connecting cable, 80 cm long

CP1W-CN811

G9SP configuration

Option units

Appearance

Order code

RS-232 option board

CP1W-CIF01

Ethernet option board (Ver. 2.0 or later)

CP1W-CIF41

Memory cassette

CP1W-ME05M

G9SP Status Display Touchscreen with 1.8 m cable

82614-0010 H-T40M-P

G9SP-N10S Display Kit (G9SP, Touchscreen, cable, CP1W-CIF01)

82612-0010 G9SP-N10S-SDK

G9SP-N10D Display Kit (G9SP, Touchscreen, cable, CP1W-CIF01)

82612-0020 G9SP-N10D-SDK

G9SP-N20S Display Kit (G9SP, Touchscreen, cable, CP1W-CIF01)

82612-0030 G9SP-N20S-SDK

G9SP-N10S kit with EtherNet/IP module

82608-0010 G9SP-N10S-EIP

G9SP-N10D kit with EtherNet/IP module

82608-0020 G9SP-N10D-EIP

G9SP-N20S kit with EtherNet/IP module

82608-0030 G9SP-N20S-EIP

Для расчета стоимости и сроков поставки пишите на нашу электронную почту:
zakaz@gcprom.ru